Deutsch English Español Francais Italiano Português
Special soluble Oil Grinding iBiotec ETERNA 3001 R
Last update: 2024/03/11 11:52

 

Next generation machining fluid

"Special rectification"

Soluble oil

iBiotec ETERNA 3001 R

 

 

Suitable for all grinding processes

Cylindrical, exterior, interior.

Level, simple, double face, with segments.

Centreless in a row or in a column.

Conical.

In mass.

Grinding (low stroke or long).

Superfinishing in a row, with bushels.

Sharpening operations.

 

Grinding of nets, syringe needles, blocks, tracks, bars, teeth, crankshafts, camshafts.

Rolling mill cylinders.

Superfinished injection molds and polished mirrors.

Guides, ejectors.

Saw blades.

 

                             Download the data sheet

 

TYPICAL PHYSICAL-CHEMICAL CHARACTERISTICS

PHYSICAL CHARACTERISTICS OF LUBRICATION OIL

CHARACTERISTIC

NORM or METHOD

VALUE

UNIT

Aspect

Visual

 Limpid

nm

Colour

Visual

Yellow to brown 

nm

Smell

Olfactory

Light, characteristic 

nm

Density at 25°C

NF EN ISO 12.185

1056

kg/m3

Freezing point

ISO 3016

-4

°C

Viscosity at 40°C

ISO 3104

16.7

 mm²/s-1

Refractive index

 

1.4240

 

pH

ISO 4925

8.6 at 5 %

 

HERBERT test

IP 287

Go to 1

%

Cast iron / steel corrosion

CNOMO

Go to 1

%

Foaming test:

at 5 % – Th 35

at 5 % – Th 20

at 5 % – Th 0

 NF T 60.188

 

300/40/0/0/250

300/40/0/0/250

300/100/0/0/250

 

 

Chlorine content

argentimetry

<20

ppm

Sulphur content

gravimetry

<50

 ppm

Nitrites content

redox

0

 

Boron content

potentiometry

0

 

Phosphorus content

calcination / colorimetry

0

 

Heavy metals content

mineralisation / spectro AA

<1

ppm

Refractometer correction coefficient

-

x1.5

 

Copper blade corrosion

NF EN ISO 2160

1a

 

Copper blade corrosion 5 %

NF EN ISO 2160

1a

 

 

ENVIRONMENTAL CHARACTERISTICS

CHARACTERISTIC

NORM or METHOD

VALUE

UNIT

DCO

ISO 15.705

13 821

mg02/l

DBO5

NF EN.1899.1

9 175

mg02/l

Free suspended matter

NF EN 872

<2

mg/L

NTK Kjeldhal nitrogen

NF EN

25 663

843

mg/N/L

 

USAGE DOSES

ETERNA 3001 R can be used at 1.5% to 2.5% in water, whatever its hardness.

NB: the refractometry correction coefficient of ETERNA 3001 R is 1.5.

A reading of 4 % with a refractometer shall determine a bath concentration of 6 %.

ETERNA 3001 R HERBERT has passed the HERBERT anti-corrosion test (1% in water). The machined parts are protected from corrosion and they do not require lubrication.

 

PRESENTATION 

 

 

 Can 20 KG

 

High Tech machining fluid (nanotechnology), for all grinding processes and all types of grinding wheels, soluble Oil soluble grinding Flat grinding Cylindrical grinding Lubricant for grinding Soluble cutting fluid Soluble fluid for grinding Machining fluids. Machining lubricants. Soluble oil grinding machine

  

Looking for another product?

Discover our entire range by clicking on the photo

 

High Tech machining fluid (nanotechnology), for all grinding processes and all types of grinding wheels, soluble Oil soluble grinding Flat grinding Cylindrical grinding Lubricant for grinding Soluble cutting fluid Soluble fluid for grinding Machining fluids. Machining lubricants. Soluble oil grinding machine

 

Manufacturing, lubrification, cleansing, protection,
IBiotec
® Tec Industries® Service 
offers a wide range of products reserved for industrial area

 


 If you wish for :

 

a free sample 
a technical advice 
a product data sheet 
a safety data sheet

 

Please contact us -

 


IBiotec® Tec Industries®Service
manufacturer of technical chemical products. 
Welcome to our website.



IBiotec® Tec Industries®Service is on : YOUTUBE